HANDRAILS FOR STAIRS, PLATFORMS AND WALKWAYS
Spacing Between Standards
Tables A and B take into account the
limiting stress for the grade of steel
specified The horizontal displacement
of any part of the barrier should not
exceed 25mm. Allowance has been
made for the combined deflection of
handrails and standards. In order to select a suitable size of
handrail standard from the above tables
one must first decide:
(a) the horizontal loading requirement
(b) the handrail diameter to be used
Having decided the handrail dia.
and loading:
(c) select from table A or Table B
a suitable standard
Note: Height should be taken from
fixing point (1) see base details
page 15.
(d) check that the handrail dia. is
compatible with the size of handrail
standard selected.
 |

For loadings on Handrails reference
should be made to BS 6399; Part 1.
Information on Design and Loadings is
also given in BS 6180. |
|

Click above to view large table
|
|

Click above to view large table
|
|
|
|
|
|
|
|
| |
|